Product overview
SYN5104 The type time integrated parameter tester is a portable time and frequency comprehensive test equipment designed and developed by Xi'an synchronous Electronic Technology Co., Ltd. The OCXO constant temperature crystal oscillator is installed inside, receiving GPS (Global Positioning System) and Beidou two generation satellite timing signal, taming the constant temperature crystal oscillator, so that the output frequency is synchronized to the satellite cesium atomic clock signal, resulting in extremely accurate time and frequency signals. Taking this as a reference, the accuracy of various input time and frequency signals can be accurately measured in real time, providing an effective and convenient solution for on-site detection, calibration and acceptance of time synchronization devices and equipment in time.
Key word : clock tester, time tester, GPS clock tester, time synchronization tester.
Product function
1) In the structural design, the three functions of time standard source, time difference measurement and test result display are integrated, so that the test items can be conveniently and accurately completed in a portable intelligent instrument.
2) The test functions are complete: time accuracy, frequency accuracy, message accuracy, Zhou Bo measurement, temperature and humidity measurement, time recording;
3) The GPS/ Beidou two generation satellite timing signal control internal oscillator provides a high precision time and frequency standard with a precision of 100 ns.
4) It can directly measure the time difference between the measured clock and standard time directly on the front panel, and the measurement method is intuitive and convenient.
5) It can be portable and can be used both in the field and in the testing organization.
6) The output time signal can be compared with a more advanced standard time source to calibrate the accuracy level of this tester. It can also be used to provide high-precision time signals to the on-the-spot equipment with demand.
7) The measured data are automatically exported to the computer.
8) It has 7AH battery powered.
Product characteristics
A) High accuracy and high cost performance.
B) Complete functions and reliable performance.
C) The frequency ratio is stored and calculated automatically.
D) High accuracy, high reliability, convenience and intuition.
Typical application
1) Power system, metrology calibration department and Research Institute.
2) It can be used in laboratory to detect and calibrate time and frequency products.
3) It can be used for testing and testing products of time and frequency manufacturers.
Technical index
Input signal | GPS/ Beidou two generation dual mode receiver | Frequency point | L1, B1 |
Timing accuracy | Less than 30ns | ||
Tracking sensitivity | -160dBm | ||
GPS Beidou two generation dual mode antenna | Number | 1 sets | |
shape | mushroom-shaped umbrella | ||
Line length | 30 meters | ||
Physical interface | BNC | ||
Bracket | Mushroom head mounting bracket | ||
Sine / pulse | Routes | 2 way | |
wave form | 1 way sine 1 way pulse | ||
level | TTL level: 0V~7V; trigger level: 2.5V AC amplitude (nominal 10MHz): 1Vpp~10Vpp | ||
frequency range | 100uHz-40MHz (pulse) 10Hz-30MHz (sine) | ||
Measurement accuracy (nominal 10MHz) | Less than 2E-8/1s Less than 2E-9/10S Less than 5E-10/100S Less than 5E-11/1000S Less than 5E-12/10000S | ||
Time difference measurement | Routes | 2 way | |
level | 2 way TTL | ||
Trigger edge | Rising / falling edge | ||
Measurement contents | Single channel measurement / dual channel measurement /1PPS measurement /1PPM measurement /1PPH measurement | ||
Measurement method | Single and continuous | ||
measurement accuracy | Less than 100ns | ||
Time record | Routes | 4 way pulse 1 (TTL) / pulse 2 (TTL) / serial port (RS232) / serial port (RS422) | |
Trigger edge | Rising / falling edge | ||
measurement accuracy | Less than 100ns (TTL) | ||
The SOE signal is measured by this function. | |||
Zhou Bo measurement | Routes | 1 way AC 220V | |
Voltage | 88~264VAC | ||
frequency | 47~63Hz | ||
Measurement accuracy: | + 0.005Hz/s | ||
Temperature and humidity measurement | Temperature measurement range | 0~50 C | |
Accuracy of temperature measurement | 25 C + 2 C | ||
Humidity measurement range | 20%~90% | ||
Humidity measurement accuracy | 25 C + 5% | ||
Serial port measurement index | Routes | 2 way | |
level | 1 way serial port (RS232) 1 way serial port (RS422) | ||
baud rate | 4800/9600/19200/38400/57600/115200 bit/s | ||
IRIG-B | level | 1 way TTL DC 1 way RS232C DC 1 way RS422/485 DC 1 way 600 Omega balanced communication 1 way unbalanced communication | |
Measurement standard | National military standard (2991A-2008) / American Standard (STD 200-04) | ||
Network input signal | NTP/SNTP test | Routes | 1 way |
Physical interface | RJ45 | ||
Agreement | NTP/SNTPV1.0-V4.0 | ||
accuracy | Less than 0.2us | ||
PTP test | Routes | 1 way | |
Physical interface | RJ45 | ||
Agreement | IEEE STD 1588 (PTPV2) | ||
Testing accuracy | Less than 50ns | ||
transport Signal out | 10MHz output | Routes | 1 way |
level | sine | ||
Range | More than 7dBm default 9dBm + 1dBm | ||
Accuracy | Less than 1E-12 (track to satellite signal 24 hours after average) Less than 5E-10 (mean value of satellite signal failure after 24 hours) | ||
Output impedance | 50 ohm | ||
Physical interface | BNC | ||
1PPS pulse signal | Routes | 1 way | |
level | TTL | ||
synchronization error | Less than 100ns | ||
Physical interface | BNC | ||
IRIG-B code output | Routes | 5 way | |
level | 1 way TTL 1 way RS232C 1 way RS422/485 1 way balanced communication 1 way unbalanced communication | ||
standard | National military standard (2991A-2008) / American Standard (STD 200-04) | ||
Serial port output | Routes | 1 way | |
level | RS232C | ||
Serial port format | RMC statement /ZDA statement /ST statement | ||
baud rate | 4800/9600/19200/38400/57600/115200 | ||
Physical interface | DB9 | ||
Environmental characteristics | working temperature | 0 C ~ + 50 C | |
relative humidity | Less than 90% (40 C) | ||
Storage temperature | -30 C ~ + 70 C | ||
storage | Routes | 2 way (1 road USB (reserved), 1 road DB9 head) | |
U disk storage (option) | Compatible with the vast majority of U disk to meet the USB2.0 protocol, insert the U disk to wait for 5S, can automatically store, as long as the test starts, the data will be automatically stored, stop testing will end the storage. | ||
Serial port communication | Send real-time measurement data to upper computer, baud rate 115200bit/s | ||
Power supply | AC 88~264VAC, 47~63Hz, power less than 40W, battery: 7AH | ||
Chassis dimensions | 4U, 19 "standard chassis. | ||
Option | Rubidium atomic oscillator, lightning arrester, customized antenna cable (50 meters, 80 meters, 100 meters, etc.), expand the output path, PTP measurement, NTP measurement, 4U standard chassis, network photoelectric conversion kit, customized products according to customer requirements. |
Guide for selection of related products
Model | Input signal | Testing function | characteristic | Other |
SYN5104 type time integrated parameter tester | GPS Beidou | Time standard source, time difference measurement, time accuracy, frequency accuracy, message accuracy, Zhou Bo measurement, temperature and humidity measurement, time recording | Most time frequency signals can be tested. | 4U, 19 "(upper rack) AC220V, 30W |
Model SYN5106 high precision clock tester | GPS Beidou | Time standard source, time difference measurement, time accuracy, frequency accuracy, timing error measurement | Clock test of electric energy meter | 4U, 19 "(upper rack) AC220V, 30W |
SYN5301 millisecond meter time calibrator | 10MHz reference | Verification of mechanical stopwatch, electronic stopwatch, pointer type electric stopwatch, millisecond meter, digital electric stopwatch and so on, combined with 4 functions of stopwatch calibrator, day difference meter / calibrator, pointer type electric stopwatch calibrator, standard time interval generator and so on. | High accuracy and powerful function | 3U, 19 "(upper rack) AC220V, 30W |
SYN5301A type stopwatch verification fixture | Control electrical signal | Verification of mechanical stopwatch, electronic stopwatch, and various kinds of timer and other fixtures. | Flexible and convenient, high automation. | Module (360x110x140mm) |
SYN5301C precision photoelectric converter | One precision laser source, one high-precision photodetector, two sets of brackets. | High precision | AC220V power adapter | |
SYN5602 calibrator for electronic parking time charge device | GPS Beidou | At the same time, 1~18 electronic parking meter (parking meter) or parking area electronic time charge device can be checked at the same time. | The targets are all superior to the requirements of the national metrological verification regulation of JJG1010-2013 electronic parking timed tariff meter. | Portable suitcase AC 220V + 10% |
SYN5603 GPS time (event) recorder | GPS | 3 pulse time recording | High accuracy | 1U, 19 "(upper rack) AC 220V + 10% |
SYN5605 multi channel time interval measuring instrument | Reference 10MHz | Simultaneous measurement of 36 pulse signals | High precision, multi-channel simultaneous measurement | 3U, 19 "(upper rack) AC 220V + 10% |
SYN5605A digital time interval measuring instrument | Reference 10MHz | Measuring the time difference between 1 or 2 pulse signals | High precision time interval measurement | 3U, 19 "(upper rack) AC 220V + 10% |
SYN5605C type time correlated single photon counting system | Reference 10MHz | Simultaneous measurement of multiple pulses | PS magnitude accuracy | 3U, 19 "(upper rack) AC 220V + 10% |
SYN5607 type phase meter | The phase difference is measured at 0 degrees to 360 degrees or + 180 degrees. | Accuracy 0.1 degree | 3U, 19 "(upper rack) AC 220V + 10% | |
SYN5608 digital phase standard | Output two adjustable sine wave with high precision phase, ultra wide voltage range and ultra low distortion. | Accuracy 0.1 degree | 3U, 19 "(upper rack) AC 220V + 10% | |
Type SYN5610 pulse generator | Reference 10MHz | Single channel, dual channel output | High precision | 4U, 19 "standard chassis. |
SYN5619 phase noise analyzer | Phase noise and stability test for 500kHz-30MHz frequency simultaneously | Less than 1E-13/1S (5E-14/1s (typical value)) 1Hz@5MHz<-140dBc (<-145dBc (typical value)) | 4U, 19 "standard chassis. | |
Option | GPS Beidou dual-mode receiver, constant temperature crystal oscillator OCXO, rubidium clock, lightning arrester, customized antenna cable (50 meters, 80 meters, 100 meters, etc.), expand the output path, PTP measurement, NTP measurement, 4U standard chassis, network photoelectric conversion kit, according to customer requirements customized products. |