SYN5619 phase noise analyzer
  • 产品详情

Product overview

The SYN5619 type phase noise analyzer is a high-precision noise tester designed by Allen synchronous Electronic Technology Co., Ltd., which is designed and developed by ourselves. The phase noise and the Allen variance are simultaneously tested.Using advanced phase measurement technology, the use of 9 Inch Touch screen, 4 core processor, 4G memory, 4G display, 60G solid state drive and industrial keyboard, etc., the switch will take about ten seconds or less within a few seconds to test results, and achieve graphical user interface.Industrial keyboard and touchscreen can be used at the same time. The operation is simple. Just press the start to test in seconds. Without skilled engineers, you can easily learn and use.

 Phase noise tester

The phase noise analyzer can display the measurement results in real time, and the results are accurate and reliable. No additional data processing, such as Allen variance calculation, is needed.The cost of accurate phase noise and Allen variance measurement is significantly reduced, covering almost all commonly used frequency sources.Achieving -140 dBc/Hz@1 Hz makes it the best choice for analyzing ultra low phase noise frequency source.

Key words: frequency stability test, phase noise tester, phase noise analyzer

Product function

1) phase noise and stability test for 500kHz-30MHz frequency simultaneously.

Product characteristics

A) simultaneously testing phase noise and stability.

 Phase noise tester


B) supports input and reference tests with different frequencies;

C) highly integrated, high precision, ultra low background;

D) fast and stable, reliable performance.

E) one button operation, LCD panel, concise and intuitive;

F) a cost-effective solution.

G) no measurement calibration requirements, save time.

Typical application

1) phased array radar, radio navigation system, automatic control system and other tests.

2) scientific research institutes and other occasions requiring high quality requirements for frequency signals.

3) in the metrology sector, high-precision oscillator equipment manufacturers or users.

Technical index

Reference and measured signals

Routes

1 roads

Physical interface

BNC

frequency range

500kHz ~ 30MHz

Input amplitude

-5dBm to +20dBm (recommended +5dBm to +15dBm)

Input impedance

50 Omega

Maximum DC voltage

+ 5V

Frequency offset analysis range

1Hz ~ 100kHz

Clutter level (5MHz)

Less than -100dBc (less than -120dBc (typical value))

Allen variance

(10MHz@0.5Hz BW)

Less than 1E-13/1S (5E-14/1s (typical value))

Less than 5E-15/1000S (1E-15/1000s (typical value))

phase noise

1Hz, @5MHz<-140dBc

(<-145dBc (typical value))

1Hz, @25MHz<-130dBc

(<-135dBc (typical value))

10kHz, @5MHz<-170dBc

(<-175dBc (typical value))

10kHz, @25MHz<-165dBc

(<-165dBc (typical value))

Preheating time

No less than 30 minutes.

Environmental characteristics

working temperature

15 centigrade to + thirty five degrees centigrade.

relative humidity

Less than 90% (40 C)

Storage temperature

-20 C ~ + 50 C

Power supply

AC 220V + 10%, 50Hz + 5%, power less than 30W

Chassis dimensions

4U, 19 "standard chassis (upper rack) 482mm (wide) X500 (deep) x178mm (high)

Option

Customized products according to customer requirements.

Guide for selection of related products

Model

Input signal

Testing function

characteristic

Other

SYN5104 type time integrated parameter tester

GPS Beidou

Time standard source, time difference measurement, time accuracy, frequency accuracy, message accuracy, Zhou Bo measurement, temperature and humidity measurement, time recording

Most time frequency signals can be tested.

4U, 19 "(upper rack)

AC220V, 30W

Model SYN5106 high precision clock tester

GPS Beidou

Time standard source, time difference measurement, time accuracy, frequency accuracy, timing error measurement

Clock test of electric energy meter

4U, 19 "(upper rack)

AC220V, 30W

SYN5301 millisecond meter time calibrator

10MHz reference

Verification of mechanical stopwatch, electronic stopwatch, pointer type electric stopwatch, millisecond meter, digital electric stopwatch and so on, combined with 4 functions of stopwatch calibrator, day difference meter / calibrator, pointer type electric stopwatch calibrator, standard time interval generator and so on.

High accuracy and powerful function

3U, 19 "(upper rack)

AC220V, 30W

SYN5301A type stopwatch verification fixture

Control electrical signal

Verification of mechanical stopwatch, electronic stopwatch, and various kinds of timer and other fixtures.

Flexible and convenient, high automation.

Module (360x110x140mm)

SYN5301C precision photoelectric converter


One precision laser source, one high-precision photodetector, two sets of brackets.

High precision

AC220V power adapter

SYN5602 calibrator for electronic parking time charge device

GPS Beidou

At the same time, 1~18 electronic parking meter (parking meter) or parking area electronic time charge device can be checked at the same time.

The targets are all superior to the requirements of the national metrological verification regulation of JJG1010-2013 electronic parking timed tariff meter.

Portable suitcase

AC 220V + 10%

SYN5603 GPS time (event) recorder

GPS

3 pulse time recording

High accuracy

1U, 19 "(upper rack) AC 220V + 10%

SYN5605 multi channel time interval measuring instrument

Reference 10MHz

Simultaneous measurement of 36 pulse signals

High precision, multi-channel simultaneous measurement

3U, 19 "(upper rack) AC 220V + 10%

SYN5605A digital time interval measuring instrument

Reference 10MHz

Measuring the time difference between 1 or 2 pulse signals

High precision time interval measurement

3U, 19 "(upper rack) AC 220V + 10%

SYN5605C type time correlated single photon counting system

Reference 10MHz

Simultaneous measurement of multiple pulses

PS magnitude accuracy

3U, 19 "(upper rack) AC 220V + 10%

SYN5607 type phase meter


The phase difference is measured at 0 degrees to 360 degrees or + 180 degrees.

Accuracy 0.1 degree

3U, 19 "(upper rack) AC 220V + 10%

SYN5608 digital phase standard


Output two adjustable sine wave with high precision phase, ultra wide voltage range and ultra low distortion.

Accuracy 0.1 degree

3U, 19 "(upper rack) AC 220V + 10%

Type SYN5610 pulse generator

Reference 10MHz

Single channel, dual channel output

High precision

4U, 19 "standard chassis.

SYN5619 phase noise analyzer


Phase noise and stability test for 500kHz-30MHz frequency simultaneously

Less than 1E-13/1S (5E-14/1s (typical value))

1Hz@5MHz<-140dBc (<-145dBc (typical value))

4U, 19 "standard chassis.

Option

GPS Beidou dual-mode receiver, constant temperature crystal oscillator OCXO, rubidium clock, lightning arrester, customized antenna cable (50 meters, 80 meters, 100 meters, etc.), expand the output path, PTP measurement, NTP measurement, 4U standard chassis, network photoelectric conversion kit, according to customer requirements customized products.Customize products with wide temperature range, and make similar products according to customer's requirements.




Home
Customer service
shopping cart
Add to Cart
BUY